Latest

Shelly catalogue, part 1: relays, dimmers, shutters and the DIN-rail Pro line

Gen3 and Gen4 in-wall relays, Mini and no-neutral models, dimmers, 0-10 V and DALI, shutters, i4 inputs, the DIN-rail Pro line and the Z-Wave Wave line: what they do and how to choose.

By 5 min read
Shelly catalogue: relays, dimmers and Pro line

This is the first part of the Shelly catalogue: everything that switches a load. Relays to turn things on and off, dimmers for lights, shutter modules, input readers and the DIN-rail devices of the Pro line. For each family we explain what it is for and which models are on sale today; sensors, plugs and energy meters are in the next guide. If you are new to the generations and protocols, start with Shelly: generations, protocols and how to choose.

Note: the Shelly catalogue changes often and the European shop lists hundreds of items across variants, colours and multipacks. Here we cover the main families and models on sale in November 2026, with the figures published by Shelly. For currents, power ratings and wiring, the datasheet of the exact model in the Shelly Knowledge Base always takes precedence. Prices are not given because they change frequently.

In-wall relays

The most common product: a module placed in the box behind the switch that turns a load on and off, while the existing push button or two-way switch keeps working.

Model Channels Metering Notes
Shelly 1 Gen4 1, 16 A No Dry (potential-free) contact: also suits gates, boilers, contactors. Powered by 110–240 V~, 24–48 V⎓ or 12 V⎓
Shelly 1PM Gen4 1, 16 A Yes Lights, sockets, pumps, appliances with consumption metering
Shelly 1 Mini Gen4 1, 8 A No Small form factor; dry contact, up to 240 V~ / 8 A and 30 V⎓ / 5 A
Shelly 1PM Mini Gen4 1, 8 A Yes Small form factor, AC loads only
Shelly 2PM Gen4 / 2PM Gen3 2 Yes Two independent circuits or one shutter, curtain or bidirectional motor
Shelly 1 Gen3, 1PM Gen3, 1 Mini Gen3, 1PM Mini Gen3 1 On PM versions Previous generation, still on sale; Matter with firmware 1.6 or later
Shelly 1L Gen3, 2L Gen3 1 or 2 No Designed for boxes without a neutral

Second-generation Plus models (Plus 1, Plus 1PM, Plus 2PM) are still installed in many homes and sold by resellers: they work well, but for a new installation choose Gen3 or Gen4.

Dimmers and lighting control

  • Shelly Dimmer Gen4 and Dimmer Gen3: in-wall dimmers for dimmable 110–240 V lamps, also work without a neutral. The Gen4 has Matter out of the box and can switch to Zigbee.
  • Shelly Dimmer 0/1-10V PM Gen4 and Gen3: control LED drivers and ballasts with a 0-10 V or 1-10 V input, with metering.
  • Shelly DALI Dimmer Gen3: dims a network of DALI luminaires.
  • Shelly Plus RGBW PM: drives 12 or 24 V⎓ LED strips, as four channels (up to 45 W per channel at 12 V and 90 W at 24 V) or as RGB/RGBW.
  • Shelly Dimmer 2: first-generation 200 W dimmer that works without a neutral, still very common.
  • Shelly Plus Wall Dimmer: wall dimmer for the North American market.

Shutters, curtains and motors

There is no separate “shutter module” in the current in-wall range: two-channel relays are used in cover mode. The Shelly 2PM Gen3 and Gen4 handle a shutter with travel calibration, position in percent and, on the Gen3, slat tilt as well. The Pro line has the Pro Dual Cover PM, which drives two shutters from the board. Shelly also sells a complete motorised curtain system with track, Wi-Fi, Bluetooth and Matter.

Inputs and interfaces

  • Shelly i4 Gen3 and Plus i4: read up to four push buttons or switches at 110–240 V~ and generate events (single, double, long press) without a relay. Use them to build “virtual keypads” that control other devices or scenes.
  • Shelly Plus i4 DC: same function for low-voltage DC inputs (5–24 V⎓).
  • Shelly Plus Uni: module for low-voltage applications.
  • Shelly Plus Add-on: galvanically isolated sensor interface, compatible with some Plus, Gen3 and Gen4 models, for temperature probes and analogue or digital sensors.

The DIN-rail Pro line

The Pro line is aimed at installers and new builds: it mounts in the distribution board, has Wi-Fi, Bluetooth and an Ethernet port, and protection against overheating, overvoltage and overcurrent.

Model Outputs Notes
Pro 1 / Pro 1PM 1 × 16 A Dry contact / with metering
Pro 2 / Pro 2PM 2 × 16 A The 2PM also drives a shutter
Pro 3 3 × 16 A Dry contacts
Pro 4PM 4 × 16 A With display and metering; a V2 with separate terminals exists
Pro Dual Cover PM 2 shutters With metering
Pro Dimmer 1PM / Pro Dimmer 2PM 1 or 2 channels Dimmers with automatic calibration and night mode
Pro Dimmer 0/1-10V PM 1 channel For 0/1-10 V LED drivers

DIN-rail energy meters (Pro 3EM, Pro EM-50 and similar) are described in the next guide.

The Wave line (Z-Wave)

Almost every relay has a Z-Wave equivalent in the Wave line: Wave 1, Wave 1PM, Wave 2PM, Wave 1 Mini, Wave 1PM Mini, Wave i4 and i4 DC, Wave Shutter, Wave Dimmer, and for the board Wave Pro 1, Pro 1PM, Pro 2, Pro 2PM, Pro 3, Pro Shutter and Pro Dimmer 1PM/2PM. The latest versions support Z-Wave Long Range. They are configured from the Z-Wave controller, not from the Shelly Wi-Fi app.

How to choose a relay

  • The load: check the allowed current and load type (resistive, inductive, LED) on the model’s datasheet, with headroom. Minis are handy but carry less current.
  • The neutral: if the box has no neutral, you need models designed to work without one (“L” series or no-neutral dimmers). We cover this in the installation guide.
  • Dry contact or not: to drive a gate, a boiler or a contactor you need a potential-free contact, like the one on the Shelly 1 Gen4 or the Pro 1.
  • Metering: PM versions cost a little more and tell you whether a load is really running, which is also useful for automations (for example “the washing machine has finished”).
  • Ecosystem: if your system revolves around Matter or Zigbee, prefer Gen4.

Sources