Latest

PoE for cameras: 802.3af, at and bt, how to work out the switch power budget and how long the cable can be

Eight PoE ports do not mean eight powered cameras: what counts is the switch's power budget in watts. The differences between 802.3af, 802.3at and 802.3bt, a worked example, cable limits, the risks of passive PoE and copper-clad aluminium cable, and what to check when a camera reboots at night.

By 5 min read

During the day the system works. At night, when the infrared LEDs switch on, one camera reboots and another drops off the NVR for a few minutes. It is not a fault: almost always the switch does not have enough watts for all of them. PoE (Power over Ethernet) carries data and power over the same network cable, but each standard has a power ceiling and each switch has a total budget that must be respected.

PoE standards compared

In PoE the device supplying power (switch, NVR with PoE ports, injector) is called the PSE; the one receiving it (the camera) is the PD. Some power is lost along the cable, which is why the standard gives two different figures.

Standard Trade name Power at the port (PSE) Power guaranteed at the device (PD) Pairs used
IEEE 802.3af (2003) PoE 15.4 W 12.95 W 2
IEEE 802.3at (2009) PoE+ 30 W 25.5 W 2
IEEE 802.3bt Type 3 (2018) PoE++ / 4PPoE 60 W 51 W 4
IEEE 802.3bt Type 4 (2018) PoE++ / 4PPoE 90 W 71.3 W 4

The standards are compatible with each other: an 802.3af camera works on an 802.3at or 802.3bt switch. The reverse is not true: a device asking for 25 W on an 802.3af port does not get the power it needs.

How much a camera really draws

The values below are orders of magnitude: the figure that matters is the maximum power consumption on your model’s data sheet, which includes infrared on and, where fitted, the heater.

Camera type Typical draw Sufficient standard
Fixed (bullet, dome, turret) with infrared 4–10 W 802.3af
Fixed with white light, motorised lens or speaker 8–13 W 802.3af (at the limit) or 802.3at
Compact PTZ 12–25 W 802.3at
Outdoor PTZ with long-range infrared, heater or wiper 30–60 W and more 802.3bt or a dedicated power supply

The switch budget: the sum to do

Every PoE switch data sheet gives two facts: the standard per port (for example “8 ports 802.3af/at”) and the total PoE budget (for example “65 W”). The second is the one often ignored: 8 ports at 30 W would make 240 W, but the switch’s power supply delivers 65 in total.

  1. Add up the maximum consumption of all cameras.
  2. Add a 20–30% margin for cable losses, start-up peaks and one more camera tomorrow.
  3. Compare the result with the switch’s total budget.

Example. Six fixed cameras at 7 W maximum and one PTZ at 22 W:

(6 × 7 W) + 22 W = 64 W
64 W × 1.25 = 80 W of budget needed

A 65 W switch copes during the day, not at night. You need a model with at least 80–90 W of budget and 802.3at ports for the PTZ.

Many managed switches show actual draw port by port in their interface (under PoE or Power): it is the quickest way to see how much margin is left. Some also let you set port priority, so that on overload the switch turns off the least important cameras first.

The cable: length, copper and gauge

  • 100 metres is the maximum length of an Ethernet link over copper, power included (90 m of fixed cable plus patch leads).
  • Use solid copper cable, Cat 5e or Cat 6. CCA (copper-clad aluminium) cables cost less but have higher resistance: voltage drops along the run, the cable warms up and the camera at the far end may not power on. They do not comply with the category standards: if the box says “CCA” or “CCAM”, leave it.
  • Within the same category, a thicker conductor (23 AWG rather than 24 or 26 AWG) reduces voltage drop on long runs.
  • Beyond 100 m you need a PoE extender mid-run, an intermediate switch, or fibre with a PoE switch near the cameras. Some switches have a “long range” mode that reaches about 250 m by dropping speed to 10 Mbit/s: for a single camera it may do, but it is not standard Ethernet.
  • Outdoors use outdoor-rated cable and, on exposed runs, surge protection: a nearby lightning strike enters the switch through the camera cable.

Beware of passive PoE

The IEEE standard includes an initial handshake: the switch checks that a PoE device is at the other end and only then applies voltage (between 44 and 57 V). Passive PoE, used by some radio equipment and old 12, 24 or 48 V injectors, puts voltage on the cable with no check at all. Connected to a device not designed for it, it can damage it; connected to an 802.3af camera, it may not power it. Always look for 802.3af/at/bt on the label.

PoE switch, NVR with PoE ports, or injector?

Solution When it makes sense Limit
NVR with built-in PoE ports Small single-brand systems: plug in and it works, cameras already isolated on an internal network Budget often small; every cable must reach the NVR
PoE switch More flexibility, more watts, cameras far from the NVR Cameras must be isolated from the rest of the network
Single PoE injector One camera to add, or a PTZ that needs more watts than the switch provides One more power supply per camera

Quick diagnosis: typical symptoms

Symptom Most likely cause Check
Camera reboots in the dark Insufficient switch budget, or an 802.3af port for a camera that needs more with infrared on Per-port draw in the switch interface; try an 802.3at injector
A distant camera does not power on Voltage drop: run too long or CCA cable Try the same camera on a short patch lead
Adding the last camera turns another one off Total budget exceeded Sum of maximum draws plus margin
Unstable 100 Mbit/s link, stuttering image Badly crimped connector or damaged cable Network tester; redo the connectors

Sources